All terms in ONE
| Label | Id | Description |
|---|---|---|
| splenocyte specimen | OBI_1110116 | [A cell specimen comprised of a mixed cell population obtained by processing whole spleen into individual cells, typically performed using a sieve or blender. This population includes T cells, B cells, macrophages, and other cell types.] |
| cultured effector T cell population | OBI_1110107 | [A cell culture including cells that have an effector T cell function] |
| material to be added | OBI_1110108 | [a material that is added to another one in a material combination process] |
| pituitary gland | UBERON_0000007 | [The pituitary gland is an endocrine gland that secretes hormones that regulate many other glands [GO]. An endocrine gland located ventral to the diencephalon and derived from mixed neuroectodermal and non neuroectodermal origin [ZFIN].] |
| contig N50 | OBI_0001941 | [N50 statistic computed for the contigs produced by the assembly process. A contig N50 is calculated by first ordering every contig by length from longest to shortest. Next, starting from the longest contig, the lengths of each contig are summed, until this running sum equals one-half of the total length of all contigs in the assembly. The contig N50 of the assembly is the length of the shortest contig in this list.] |
| grant agency | OBI_0001942 | [An organization that provides funding support for projects such as investigations.] |
| software pipeline | OBI_0001943 | [A plan specification that specifies a chain encoded in software of processing elements (processes, threads, coroutines, etc.), arranged so that the output of each element is the input of the next. Usually some amount of buffering is provided between consecutive elements.] |
| sequence annotation | OBI_0001944 | [A planned process that identifies and reports sequence features (e.g. protein coding regions) in sequence data.] |
| sequence feature annotation | OBI_0000905 | [Information about a sequence region] |
| Bruker SPE-NMR platform | OBI_0000613 | [A Solid Phase Extraction (SPE) system provides an interface between liquid chromatography (LC) and NMR. For the process of LC-SPE NMR a chromatographic separation is done and the peaks of interest are trapped on an individual SPE cartridge after the column. The peak selection is done either by UV detection or by evaluation of the on-line registered MS or MSn spectra.] |
| Bruker MATCH tube holder system | OBI_0000612 | [The Bruker Multiple Adjustable Tube Clamp Holder MATCH system is a holder for 100 mm long NMR sample tubes with diameters ranging from micro tubes up to 5 mm NMR tubes. The MATCH insert fits into a standard 10 mm Bruker spinner and is suitable for all non-spinning applications.n The MATCH system provides an easy and cost efficient means of optimizing the signal-to-noise ratio of each sample. By matching the NMR tube diameter to the size of the sample, most of the sample can be placed in the active column of the NMR coil. This leads to an enhanced signal detection compared to diluting the same sample quantity in a larger tube.] |
| auto injector | OBI_0000610 | [A gas chromatography device that can auto-inject a small number of samples an inlet.] |
| count | APOLLO_SV_00000032 | [A measurement datum that is the output of counting.] |
| chromatography splitter | OBI_0000619 | [An adjustable restriction that is placed in the waste outlet to allow the necessary pressure to develop at the column inlet to force a flow (q ml/min) through the column. If the flow of mobile phase is Q ml/min then the waste flow will be (Q-q) ml/min. by adjusting the waste flow, the proportion of the sample entering the capillary column can be varied over a wide range of values and the necessary minimum permissible volume for the particular column in use can be selected for analysis. Unfortunately, the fraction taken in this way may not be representative of the original sample. This is due to the individual solutes in the mixture having different diffusivities and, thus, they distribute themselves across the sampling tube in an irregular manner. In general, the components with higher diffusivities (e.g., those solutes of lower molecular weight) will diffuse away from the bulk sample more quickly than those having lower diffusivities.] |
| fluorine-induced chemiluminescence detector | OBI_0000617 | [A gas chromatographic detection system based on the low pressure, gas phase chemiluminescence of the reaction mixture of molecular fluorine with organo-sulfur, -selenium, and -tellurium compounds separated from (gas phase) headspace samples. This detector was originally developed in the research group of John Birks at the University of Colorado, USA and was manufactured and sold by Sievers Instruments (Boulder Colorado, USA). This system can be divided up into three parts: the chromatograph, transfer line, and reaction cell; PMT and photon counting electronics; and the molecular fluorine generator.] |
| high resolution probe with automatic tuning and matching | OBI_0000616 | [The Automatic Tuning and Matching (ATM) option for AVANCE spectrometers is available for double resonance probes in fixed-frequency and broadband tunable configurations with either direct or indirect detection. Thus, for multinuclear operation, as often required for applications in inorganic chemistry, ATM facilitates the accurate setting of 90 degree pulse widths on both observe and decoupling channels for each chosen nucleus and each individual sample - even with full automation. Triple resonance probes in fixed-frequency configurations, as typically used for inverse detection with high-field systems.] |
| protein expression profiling assay | OBI_0000615 | [An assay that determines protein expression and translation activity using protein extracts collected from a material entity.] |
| guard column | OBI_0000614 | [Guard columns are installed between the injection valve and the analytical or preparative column and here will remove contaminants and prolong the lifetime of the columns.] |
| counting | APOLLO_SV_00000033 | [The planned process of finding the number of elements in a finite set of objects.] |
| scaffold N50 | OBI_0001945 | [N50 statistic computed for the scaffold produced by the assembly process. The method for computing the value is similar to that of contig N50 but uses scaffold information instead of contig information] |