All terms in ONE
| Label | Id | Description |
|---|---|---|
| BioSorter1000 | OBI_0400014 | [A BioSorter1000 is a flow_cytometer_sorter manufactured by Union Biometrica. It includes analog electronics, 488/514 nm multi-line Argon-ion laser for fluorescence and a light stabilized 670 nm forward scatter laser for extinction and time-of-flight. It has filters and PMTs for 3 fluorescent parameters and photodiodes for scatter, time of flight, and extinction. The flow cell is quartz cuvette. The BioSorterTM 1000 is an instrument for analyzing and sorting objects from 200-600 microns in diameter.] |
| BioSorter2000 | OBI_0400015 | [A BioSorter2000 is a sorter manufactured by Union Biometrica. It includes analog electronics, 488/514 nm multi-line Argon-ion laser for fluorescence and a light stabilized 670 nm forward scatter laser for extinction and time-of-flight. It has filters and PMTs for 3 fluorescent parameters and photodiodes for scatter, time of flight, and extinction. The flow cell is quartz cuvette. The BioSorterTM 2000 is an instrument for analyzing and sorting objects from 500 microns to 1.5 millimeters in diameter.] |
| Bactiflow | OBI_0400012 | [A Bactiflow is a flow_cytometer_analyser manufactured by Chemunex SA. It is a cell counter for bacteria and other micro organisms. Bacteria are stained with a fluorochrome and the number of particles that fluoresce are counted. The system uses digital electronics, a single laser and a single detector. An ALS version is available as well - Automatic Labeling System. The Bactiflow is specialized cytometer used exclusively for counting microbes.] |
| band pass filter | OBI_0400013 | [A band pass filter is an optical filter that passes wavelengths of light within a certain range and rejects (attenuates) frequencies outside that range. The passed wavelengths are indicated in the specifications of the filter and its name. A 480/20 band-pass filter pass light with at wavelengths of 460 to 500 nm and attenuates all others.] |
| diagram | IAO_0000309 | [A figure that expresses one or more propositions] |
| document title | IAO_0000305 | [A textual entity that names a document] |
| study design dependent variable | OBI_0000751 | [dependent variable specification is part of a study design. The dependent variable is the event studied and expected to change when the independent variable varies.] |
| study design independent variable | OBI_0000750 | [a directive information entity that is part of a study design. Independent variables are entities whose values are selected to determine its relationship to an observed phenomenon (the dependent variable). In such an experiment, an attempt is made to find evidence that the values of the independent variable determine the values of the dependent variable (that which is being measured). The independent variable can be changed as required, and its values do not represent a problem requiring explanation in an analysis, but are taken simply as given. The dependent variable on the other hand, usually cannot be directly controlled] |
| right handedness | PATO_0002203 | [Handedness where the organism preferentially uses the right hand or foot for tasks requiring the use of a single hand or foot or a dominant hand or foot.] |
| table of abbreviations | IAO_0000307 | [A table where the constituent texts are abbreviations and their expansions] |
| ambidextrous handedness | PATO_0002204 | [Handedness where the organism exhibits no overall dominance in the use of right or left hand or foot in the performance of tasks that require one hand or foot or a dominant hand or foot.] |
| CytoSub | OBI_0400029 | [A CytoSub is a flow_cytometer_analyser manufactured by Cyto Buoy Inc. They are a single laser, multi parameter instrument. Various types of micro-laser are offered; available measuring parameters are forward light scatter, side scatter, and fluorescence (max. 9 colour bands). The current series have 5 parameters. The CytoSub is the submersible version equipped with a high pressure sample inlet loop and a high pressure housing to allow underwater operation down to 200 m, lowered on a cable or mounted on a flooded underwater vehicle.] |
| citation | IAO_0000301 | [A textual entity intended to identify a particular publication.] |
| background corrected data visualization | OBI_0200193 | [A data visualization which has input of a background corrected data set and produces an output of a report graph which is capable of rendering data of this type.] |
| author identification | IAO_0000302 | [A textual entity intended to identify a particular author] |
| CytoBuoy flow cytometer analyzer | OBI_0400027 | [A flow cytometer analyser which is manufactured by Cyto Buoy Inc. They are the buoy mounted version of the CytoSense, equipped with wireless transmission of control and data files. They are a single laser, multi parameter instrument. Various types of micro-laser are offered; available measuring parameters are forward light scatter, side scatter, and fluorescence (max. 9 colour bands). The current series have 5 parameters.] |
| institutional identification | IAO_0000303 | [A textual entity intended to identify a particular institution] |
| proportional hazards model estimation | OBI_0200195 | [Proportional hazards model is a data transformation model to estimate the effects of different covariates influencing the times-to-failure of a system.] |
| CytoSence | OBI_0400028 | [A CytoSense is a flow_cytometer_analyser manufactured by Cyto Buoy Inc. They are a single laser, multi parameter instrument. Various types of micro-laser are offered; available measuring parameters are forward light scatter, side scatter, and fluorescence (max. 9 colour bands). The current series have 5 parameters. The CytoSense is the basic instrument, which can be used for normal laboratory applications, as well as for autonomous monitoring with internal data logging or direct data transmission. The special instrument design and its splashproof housing allow operation on moving platforms and outdoor sites.] |
| caption | IAO_0000304 | [A textual entity that describes a figure] |