All terms in ONE
| Label | Id | Description |
|---|---|---|
| differential pressure gauge | OBI_0400032 | [Part of the fluidics subsystem. The differential pressure gauge monitors the difference between sample and sheath fluid pressures in systems where pressure is used to force the sample fluid to flow in the center of the sheath fluid. A differential pressure gauge can be used by the operator to make sure that the sample fluid is at a greater pressure than the sheath fluid, which maintains a core of sample fluid.] |
| diode laser | OBI_0400033 | [A diode laser is a laser in which the active medium is a p-n junction semiconductor laser diode, similar to that found in a light-emitting diode. Laser diodes emit at wavelengths from 375 nm to 1800 nm, and wavelengths of over 3 micrometer have been demonstrated. A diode laser can by used to irradiate cells in a flow cytometer.] |
| dichroic filter | OBI_0400030 | [A dichroic filter is an optical filter which is used to selectively pass light of a small range of colors while reflecting other colors. A dichroic filter passes the specified range of light whereas a dichroic mirror reflects the specified range of light.] |
| cortex of kidney | UBERON_0001225 | [Outer cortical portion of the kidney, between the renal capsule and the renal medulla.] |
| dichroic mirror | OBI_0400031 | [A dichroic mirror is an optical filter which is used to selectively reflect light of a small range of colors while passing other colors. A dichroic filter passes the specified range of light whereas a dichroic mirror reflects the specified range of light.] |
| digestive system secreted substance | UBERON_0006911 | |
| FACS Calibur | OBI_0400036 | [The FACS Calibur is one of the most popular cytometers in use for research.] |
| FACS Canto | OBI_0400037 | [A FACS_Canto is a flow_cytometer_analyser manufactured by Becton Dickinson. It features digital electronics, a solid state 488 nm, and a HeNe 633 nm lasers, and filters and PMTs for collecting up to 6 fluorescent parameters. The FACS_Canto is an analyser usually used in clinical applications.] |
| dye laser | OBI_0400034 | [A dye laser is a laser in which the lasing medium is a fluorescent dye, usually dissolved in an organic solvent such as ethanol or ethylene glycol. The particular dye used determines the wavelengths the laser can emit. The laser medium is places between two parallel mirrors for light emission amplification.] |
| restriction enzyme | OBI_0000732 | [an enzyme that has a specific target cleavage sites within nucleic acids] |
| pyrosequencing assay | OBI_0000730 | [A DNA sequencing by synthesis assay which sequences a single strand of DNA by synthesizing the complementary strand along it, one base pair at a time, and detecting which base was actually added at each step. The template DNA is immobilized, and solutions of A, C, G, and T nucleotides are added and removed after the reaction, sequentially. Light is produced only when the nucleotide solution complements the first unpaired base of the template. The sequence of solutions which produce chemiluminescent signals allows the determination of the sequence of the template. ssDNA template is hybridized to a sequencing primer and incubated with the enzymes DNA polymerase, ATP sulfurylase, luciferase and apyrase, and with the substrates adenosine 5-prime phosphosulfate (APS) and luciferin.] |
| Guava EasyCyte Plus | OBI_0400049 | [A Guava_EasyCyte_Plus System is a flow_cytometer_analyser that includes a single 488 nm laser, and filters and PMTs to collect up to 4 fluorescent parameters. It includes a photodiode forward scatter collector and an optional photodiode for side scatter collection.Guava cytometers use aspiration instead of fluid systems to transport cells within the machine. The EasyCyte plus accepts 96 well plates as well as tubes. The Guava_EasyCyte_Plus cytometer is a small portable cytometer particularly useful for field measurement.] |
| Student's t-test | OBI_0000739 | [Studen't t-test is a data transformation with the objective of a statistical hypothesis test in which the test statistic has a Student's t distribution if the null hypothesis is true. It is applied when the population is assumed to be normally distributed but the sample sizes are small enough that the statistic on which inference is based is not normally distributed because it relies on an uncertain estimate of standard deviation rather than on a precisely known value.] |
| restriction enzyme based cloning | OBI_0000738 | [restriction enzyme based cloning is a recombinant vector cloning process that has as an input genetic material that was cleaved with restriction enzymes, and a cloning vector that was cleaved with complementary restriction enzymes. It uses ligase to chemically join the input genetic material and the cloning vector to create a recombinant vector.] |
| sodium citrate dihydrate | CHEBI_32142 | [The dihydrate of trisodium citrate.] |
| single fragment library | OBI_0000736 | [is a collection of short tags from DNA fragments, are extracted and covalently linked as single tag constructs] |
| NTP-2000 | OBI_0000735 | [a material consisting of 14.5% protein, 8.5% fat and 9.5% fiber produced to feed rodents] |
| obscuration bar | OBI_0400078 | [An obscuration bar is a an optical subsystem which is a strip of metal or other material that serves to block out direct light from the illuminating beam. The obscuration bar prevents the bright light scattered in the forward directions from burning out the collection device.] |
| FACSvantage | OBI_0400041 | [The FACSvantage is a flow_cytometer_sorter manufactured by Becton Dickinson. It has analog electronics, three lasers (several options are available), and the filters and PMTs to collect 6 fluorescent parameters and side scatter, and a photodiode to collect forward scatter. The FACSvantage can be used to analyse, sort and collect cells.] |
| FC 500 | OBI_0400042 | [A FC_500 is a flow_cytometer_analyser manufactured by Beckman Coulter. It features digital electronics, 488 nm and 635 nm lasers, filters and PMTs for 5 fluorescent parameters, a diode for collecting side scatter and a solid state detector for forward scatter. The FC 500 is an analyser usually used for either research or clinical applications.] |