All terms in ONE
| Label | Id | Description |
|---|---|---|
| Bruker autosampler | OBI_0000464 | [A Bruker autosampler is an autosampler made by Bruker.] |
| autosampler | OBI_0000555 | [An optional part of an NMR instrument used to hold samples prior to NMR analysis and that sequentially loads these samples into the analytical part of the NMR instrument. n alt The autosampler is an automatic sample changer device.] |
| detection of specific nucleic acids with complementary probes assay measuring epitope specific macrophage inflammatory protein-1 alpha production by T cells | OBI_0001792 | [An assay of epitope specific macrophage inflammatory protein-1 alpha production by T cells that uses a detection of specific nucleic acids with complementary probes assay.] |
| polynomial transformation | OBI_0200093 | [A polynomial transformation is a data transformation that is obtained through a polynomial, where a polynomial is a mathematical expression involving a sum of powers in one or more variables multiplied by coefficients (e.g. see http://mathworld.wolfram.com/Polynomial.html). The number of variables and the degree are properties of a polynomial. The degree of a polynomial is the highest power of its terms, where the terms of a polynomial are the individual summands with the coefficients omitted.] |
| interleukin-25 production | GO_0032629 | [The appearance of interleukin-25 due to biosynthesis or secretion following a cellular stimulus, resulting in an increase in its intracellular or extracellular levels.] |
| cytometric bead array assay measuring epitope specific lymphotoxin A production by T cells | OBI_0001793 | [An assay of epitope specific lymphotoxin A production by T cells that uses a cytometric bead array assay.] |
| cytometric bead array assay measuring epitope specific tumor necrosis factor superfamily cytokine production by T cells | OBI_0001368 | [An assay of epitope specific tumor necrosis factor superfamily cytokine production by T cells that uses a cytometric bead array assay.] |
| column chromatography detector | OBI_0000463 | [There is a wide range of detectors available for both GC and LC each having their own particular areas of application. In general the more catholic the response, the less sensitive the detector and the most sensitive detectors are those that have a specific response. The performance of all detectors should be properly specified so that the user can determine which is most suitable for a specific application. Such specifications are also essential to compare the performance of different detectors supplied by alternative instrument manufactures. Detector specifications should be presented in a standard form and in standard units, so that detectors can be compared that function on widely different principles.] |
| Westfall and Young family wise error rate correction | OBI_0200092 | [Is a data transformation process in which the Westfall and Young method is applied with the aim of controlling for multiple testing] |
| family wise error rate correction method | OBI_0200073 | [A family wise error rate correction method is a multiple testing procedure that controls the probability of at least one false positive.] |
| p-value | OBI_0000175 | [A quantitative confidence value that represents the probability of obtaining a result at least as extreme as that actually obtained, assuming that the actual value was the result of chance alone.] |
| multiple testing correction objective | OBI_0000791 | [A multiple testing correction objectives is a data transformation objective where the aim is to correct for a set of statistical inferences considered simultaneously] |
| FWER adjusted p-value | OBI_0001265 | [A quantitative confidence value resulting from a multiple testing error correction method which adjusts the p-value used as input to control for Type I error in the context of multiple pairwise tests] |
| interleukin-24 production | GO_0032628 | [The appearance of interleukin-24 due to biosynthesis or secretion following a cellular stimulus, resulting in an increase in its intracellular or extracellular levels.] |
| survival analysis objective | OBI_0200083 | [A data transformation objective which has the data transformation aims to model time to event data (where events are e.g. death and or disease recurrence); the purpose of survival analysis is to model the underlying distribution of event times and to assess the dependence of the event time on other explanatory variables] |
| spread calculation data transformation | OBI_0200086 | [A spread calculation is a data transformation that has objective spread calculation.] |
| cytometer | OBI_0400137 | [A cytometer is an instrument for counting and/or measuring characteristics of cells.] |
| photodetector | OBI_0400082 | [A photodetector is a device used to detect and measure the intensity of radiant energy through photoelectric action. In a cytometer, photodetectors measure either the number of photons of laser light scattered on impact with a cell (for example), or the flourescence emitted by excitation of a fluorescent dye.] |
| optical filter | OBI_0400079 | [An optical filter is an optical subsystem that selectively transmits light having certain properties (often, a particular range of wavelengths, that is, range of colours of light), while blocking the remainder. They are commonly used in photography, in many optical instruments, and to colour stage lighting Optical filters can be arranged to segregate and collect light by wave length.] |
| mass spectrometry analysis | OBI_0200085 | [A data transformation which has the objective of spectrum analysis.] |