All terms in ONE
| Label | Id | Description |
|---|---|---|
| email address of Bioinformatics Resource Center contact person | OBI_0001887 | [An email address of the person who is contact representative of a Bioinformatics Resource Center] |
| sequencing facility contact person | OBI_0001888 | [A person who is the contact representative at the sequencing facility] |
| specimen provider principal investigator | OBI_0001889 | [A person who is a principal investigator and provides the specimen] |
| Varian UNITY INOVA spectrometer | OBI_0000558 | [The UNITY INOVA is also the easiest spectrometer to use and is also the choice of those interested in using advanced NMR techniques in their own research, but without becoming, or hiring, an NMR expert. A complete set of turnkey operating environments is available for the UNITY INOVA covering the structure and dynamics of biological macromolecules, small molecules, solids, and imaging. These packages put the combined NMR expertise of the entire Varian NMR community at your fingertips.] |
| flash pump system | OBI_0000557 | [Any pump system used in flash column chromatography to push the solvent through the column. Better flow rates can be achieved by using a pump or by using compressed gas (e.g. air, nitrogen, or argon) to push the solvent through the column (flash column chromatography).] |
| isocratic pump system | OBI_0000556 | [A pump system optimized for isocratic chromatography.] |
| gas chromatography oven | OBI_0000554 | [A gas chromatography oven is an oven with a heated connection between the GC and the MS instrument in a GCMS-analysis, that keeps compounds in the gas phase as they leave the GC oven.] |
| gas chromatography equipment | OBI_0000542 | [Any device used in a gas chromatography experiment.] |
| Bruker Capillary LC-NMR platform | OBI_0000553 | [Capillary LC-NMR is a hyphenated technique coupling capillary liquid chromatography and NMR, which increases sensitivity dramatically through the use of miniaturization of the chromatographic techniques and NMR detection volume. LC-NMR hyphenated systems separate a mixture into its pure components and couple the output to NMR for automatic sample analysis. The ever increasing need to measure lower sample amounts and lower level impurities demands the highest NMR sensitivity. Traditional LC-NMR systems with relatively large peak volumes are not optimized for such low levels of detection. Bruker BioSpin, together with Waters and Protasis has developed a Capillary LC-NMR system. The latest capillary LC attributes and highest capillary flow probe sensitivity combine with state of the art NMR systems technology. Greater mass sensitivity and faster spectral analysis with smaller sample volumes is possible. This system is ideal for analysis of metabolites and impurities associated with the drug development process.] |
| Bruker NMR instrument | OBI_0000596 | [An NMR instrument that is manufactured by Bruker.] |
| organization of specimen provider principal investigator | OBI_0001880 | [An organization that is the affiliation of the principal investigator providing the specimens for the investigation] |
| organization of Bioinformatics Resource Center contact person | OBI_0001881 | [An organization that is the affiliation of the person who is contact representative of a Bioinformatics Resource Center] |
| needle assembly | OBI_0000551 | [The needle assembly attached to the autosampler, comprises the injector needle that feeds a sample or carrier gas into the inlet] |
| liquid NMR probe | OBI_0000559 | [An NMR probe that is designed to hold a liquid sample.] |
| organization of specimen collector | OBI_0001893 | [An organization that is the affiliation of the person collecting the specimen] |
| email address of sequencing facility contact person | OBI_0001894 | [An email address of the contact representative at the sequencing facility] |
| specimen collector | OBI_0001895 | [A person who collects the specimen] |
| investigation assay specification | OBI_0001896 | [A plan specification which indicates the assay type used to obtain data.] |
| vagina | UBERON_0000996 | [A fibromuscular tubular tract leading from the uterus to the exterior of the body in female placental mammals and marsupials, or to the cloaca in female birds, monotremes, and some reptiles[WP].] |
| organization of sequencing facility contact person | OBI_0001897 | [An organization that is the affiliation of the contact representative at the sequencing facility] |